Installation, Operation
and
4
CHTV
(Supersedes PQ431)
PQ431
RENEWAL PARTS IDENTIFICATION
161-058058-001
JULY, 1983
®
Type CHTV Horizontal Vaporizers for Dowtherm ,
®
Therminol and Other Organic Fluids
(Temperatures to 750°F at 150 psi, 15 kW thru 300 kW)
System Model Number and Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customer’s Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Customer’s Order Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
National Board Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications & Dimensions
Ampere*
Model Number
Oil &
Dust Tight
NEMA XII
Dimensions
(In.)
Weight
(Lbs.)
Weather-
resistant
NEMA IV
Explosion-
resistant
Class1, Group D
Standard
NEMA I
Operating
Volume
w/o
Controls
kW
BTUH
240V
480V
L
W
H
15
20
25
30
40
50
51,180
68,240
36.0
48.1
60.1
72.2
96.2
120.3
18.0
24.0
30.1
36.1
48.1
60.1
CHTV-316-15
CHTV-316-20
CHTV-316-25
CHTV-316-30
CHTV-316-40
CHTV-316-50
CHTVO-316-15
CHTVO-316-20
CHTVO-316-25
CHTVO-316-30
CHTVO-316-40
CHTVO-316-50
CHTVW-316-15
CHTVW-316-20
CHTVW-316-25
CHTVW-316-30
CHTVW-316-40
CHTVW-316-50
CHTVX-316-15
CHTVX-316-20
CHTVX-316-25
CHTVX-316-30
CHTVX-316-40
CHTVX-316-50
15.7
19.4
23.6
27.2
35.6
43.5
80
94
110
124
156
186
36
36
36
36
36
36
50
50
50
50
50
50
600
700
78,500
825
102,360
136,480
157,000
925
1175
1400
40
50
136,480
157,000
204,720
235,500
341,200
96.2
120.3
144.3
180.4
240.6
48.1
60.1
CHTV-624-40
CHTV-624-50
CHTV-624-60
CHTV-624-75
CHTV-624-100
CHTVO-624-40
CHTVO-624-50
CHTVO-624-60
CHTVO-624-75
CHTVO-624100
CHTVW-624-40
CHTVW-624-50
CHTVW-624-60
CHTVW-624-75
CHTVW-624-100
CHTVX-624-40
CHTVX-624-50
CHTVX-624-60
CHTVX-624-75
CHTVX-624-100
75.0
106.0
137.0
168.0
218.0
95
111
125
149
187
48
48
48
48
48
60
60
60
60
60
1200
1450
1600
1900
2350
60
72.2
75
100
90.2
120.3
100
125
150
175
200
341,200
392,500
511,800
549,500
682,400
240.6
120.3
150.4
180.4
210.5
240.6
CHTV-1230-100 CHTVO-1230-100 CHTVW-1230-100
CHTV-1230-125 CHTVO-1230-125 CHTVW-1230-125
CHTV-1230-150 CHTVO-1230-150 CHTVW-1230-150
CHTV-1230-175 CHTVO-1230-175 CHTVW-1230-175
CHTV-1230-200 CHTVO-1230-200 CHTVW-1230-200
CHTVX-1230-100
CHTVX-1230-125
CHTVX-1230-150
CHTVX-1230-175
CHTVX-1230-200
218.0
222.0
263.0
300.0
340.0
111
129
149
167
187
54
54
54
54
54
66
66
66
66
66
2400
2700
3100
3500
3950
–
–
–
–
225
250
275
300
767,700
853,000
–
–
–
–
271.0
301.0
331.0
361.0
CHTV-1836-225 CHTVO-1836-225 CHTVW-1836-225
CHTV-1836-250 CHTVO-1836-250 CHTVW-1836-250
CHTV-1836-275 CHTVO-1836-275 CHTVW-1836-275
CHTV-1836-300 CHTVO-1836-300 CHTVW-1836-300
CHTVX-1836-225
CHTVX-1836-250
CHTVX-1836-275
CHTVX-1836-300
379.0
417.0
455.0
490.0
149
162
175
187
60
60
60
60
72
72
72
72
4600
5200
5600
6000
938,300
1,023,600
*All amperes based on 3ph 60 cycle power.
ASME Relief Valve
Pressure Gage
Level Switch
Hartford Loop
Spare or Fill
Inspection Ports (2)
Vent
Sight Glass
H
Heater Terminal Cover
L
W
© 2010 Chromalox, Inc.
INSTALLATION
blocks and the ground lug in the heater terminal enclosure.
CAUTION: Hazard of Electric Shock. The vaporizer
must be grounded using the grounding means pro-
vided in the heater terminal box and in the control
box, and employ wiring in accordance with the
National Electrical Code.
C. With all controls mounted on the same skid with the
hydraulic or mechanical part of the vaporizer. The unit is
completely wired. The only wiring necessary is to terminals
L1, L2 and L3 on the main circuit breaker and the ground-
ing lug in the control panel.
1. The vaporizer is normally supplied one of three different ways:
A. Without controls as they are going to be provided by the
customer. The customer will have to wire from his supplied
controls to the level or float switch on the vessel, and to the
heater terminal blocks and the ground lug in the heater ter-
minal enclosure.
2. Note: All electrical connections should be checked and tight-
ened if necessary. These sometimes loosen in transit.
CAUTION: Hazard of Electric Shock. Disconnect all
power before servicing the vaporizer.
B. With controls supplied, but mounted remotely by the user.
The customer will have to wire from remote controls to the
level or float switch on the vessel, and to the heater terminal
WIRING DIAGRAMS
Typical Wiring Diagram
15 to 100 kW (All Voltages)
Typical Wiring Diagram
125 to 300 kW 440/480 and 550/575V
Circuit
Breaker
Circuit
Breaker
C1
F1
F2
F3
C1
C2
C3
C4
L1
L2
L3
L1
L3
F1
F2
F3
L2
F7
F8
F9
F4
F5
F6
F10
F11
F12
C2
F4
F5
F6
F14
F13
H4
F7 F8
H4
H4 H2 H3 H1 H4 H2 H3 H1
H2
H4 H2 H3 H1 H4 H2 H3 H1
240V 480V
Transformer Primary
H3
H1
240V
480V
H1
H3
H2
Transformer Primary
F15
On
F9
X1
X2
Pilot LIght
R
G
Off
Feed or Condensate
Return Pump (Optional)
Pilot Light
Low Level and
High Limit Circuit
3
4
X1 120-Volt X2
4
M
Pilot Light
R
G
A
A
FS2
FS1
Off
OPC
On
On
FS2
Feed or Condensate
Return Pump (Optional)
Pilot Light
OPC
7
5
6
M
3
5
7
1CR
FS-1
1CR
CR
X2
X1
High Limit Circuit
Pilot Light
Heat #1
Pilot Light
6
Off On
Pilot Light
Heat #1
Pilot LIght
Heat #2
Pilot LIght
Heat #3
Pilot LIght
Heat #4
A
A
A
A
1CR
8
PSI-1
Off
Off
9
C1
C2
C3
C4
C1
C2
1
2
3
4
Stepper
9
8
Off On
Off On
Off On
A+
10
12
14
4-20MA
11
1CR
On PSI-2
10
Input
B-
Heat #2
11
12
13
15
C
D
E
135 ohm
Input
OPERATION
CAUTION: To avoid possible damage to the heaters, do not ener-
float switch located on the vessel, so that the heating element
will shut off automatically in case of a low liquid level.
4. Operate the vaporizer until 220°F is reached. Periodically open
the bleed valves to remove air from the system. At 220°F any
moisture that has been trapped in the system will flash into
steam and can be bled off through the bleeder valves.
gize the heaters until the vaporizer is filled with fluid.
1. The filling of the Chromalox CHTV type horizontal vaporizer
is accomplished in one of two ways:
A. On vaporizers with gravity return type condensate return
systems, the filling is done simply by pouring the heat
transfer or other organic media into the vaporizer shell
using the spare or fill nozzle and, while the filling is taking
place, bleeding the displaced air from the vent.
B. On vaporizers that use pump condensate return systems or
on systems where the condensate is not returned, the filling
would be done by first filling the condensate return tank or
supply or reservoir tank and then energizing the condensate
return or supply pump. While the vaporizer vessel is being
filled, the vent nozzle should be opening for bleeding out
the air.
WARNING: Avoid having the heat transfer fluid or the fluid to be
vaporized spilled or leaked into the pipeline or vessel insulation as
it has been found that spontaneous ignition of some of these fluids
may result at elevated temperatures.
5. After the vaporizer has been completely charged and free of
steam pockets, set the controlling pressure switch or thermostat to
the pressure or temperature point where the fluid will vaporize.
6. Operate the vaporizer until this set point is reached.
Periodically open the bleeder valves to remove air from the
system.
2. Set the thermostat at 220°F and/or the controlling pressure
switch at its equivalent.
3. To energize the heaters, turn the “on-off” selector switch to the
“on” position. The heaters are interlocked with the level or
7. After the system is completely free of air, set the controlling
pressure switch or thermostat to the desired operating point.
MAINTENANCE
2. The tank should be checked regularly for sediment around the
CAUTION: Hazard of Severe Shock. Disconnect all
power to heater before servicing or replacing
heaters.
heater as sediment can act as an insulator and shorten heater life.
3. Remove any accumulated sludge deposits form heater and
from tank.
1. Heaters should be checked periodically for coatings and corro-
4. Check for loose terminal connections and tighten if necessary.
sion and cleaned if necessary.
RENEWAL PARTS IDENTIFICATION
Vaporizer
Model No.
Heating Element Part Number
CHTV, CHTVO, CHTVW
or CHTVX
240V
480V
316-15
316-20
316-25
316-30
316-40
316-50
063-122121-001
063-122121-003
063-122121-005
063-122121-007
063-122121-013
063-122121-017
063-122121-002
063-122121-004
063-122121-006
063-122121-008
063-122121-014
063-122121-018
624-40
624-50
624-60
624-75
624-100
063-122121-003
063-122121-005
063-122121-007
063-122121-011
063-122121-017
063-122121-004
063-122121-006
063-122121-008
063-122121-012
063-122121-018
1230-100
1230-125
1230-150
1230-175
1230-200
063-122121-005
063-122121-009
063-122121-011
063-122121-015
063-122121-017
063-122121-006
063-122121-010
063-122121-012
063-122121-016
063-122121-018
1836-225
1836-250
1836-250
1836-300
063-122121-011
063-122121-012
063-122121-019
063-122121-020
063-122121-018
063-122121-017
Limited Warranty:
Please refer to the Chromalox limited warranty applicable to this product at
2150 N. RULON WHITE BLVD., OGDEN, UT 84404
Phone: 1-800-368-2493
|