Chromalox Humidifier PQ431 User Manual

Installation, Operation  
and  
4
CHTV  
(Supersedes PQ431)  
PQ431  
RENEWAL PARTS IDENTIFICATION  
161-058058-001  
JULY, 1983  
®
Type CHTV Horizontal Vaporizers for Dowtherm ,  
®
Therminol and Other Organic Fluids  
(Temperatures to 750°F at 150 psi, 15 kW thru 300 kW)  
System Model Number and Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Customer’s Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Customer’s Order Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
National Board Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Specifications & Dimensions  
Ampere*  
Model Number  
Oil &  
Dust Tight  
NEMA XII  
Dimensions  
(In.)  
Weight  
(Lbs.)  
Weather-  
resistant  
NEMA IV  
Explosion-  
resistant  
Class1, Group D  
Standard  
NEMA I  
Operating  
Volume  
w/o  
Controls  
kW  
BTUH  
240V  
480V  
L
W
H
15  
20  
25  
30  
40  
50  
51,180  
68,240  
36.0  
48.1  
60.1  
72.2  
96.2  
120.3  
18.0  
24.0  
30.1  
36.1  
48.1  
60.1  
CHTV-316-15  
CHTV-316-20  
CHTV-316-25  
CHTV-316-30  
CHTV-316-40  
CHTV-316-50  
CHTVO-316-15  
CHTVO-316-20  
CHTVO-316-25  
CHTVO-316-30  
CHTVO-316-40  
CHTVO-316-50  
CHTVW-316-15  
CHTVW-316-20  
CHTVW-316-25  
CHTVW-316-30  
CHTVW-316-40  
CHTVW-316-50  
CHTVX-316-15  
CHTVX-316-20  
CHTVX-316-25  
CHTVX-316-30  
CHTVX-316-40  
CHTVX-316-50  
15.7  
19.4  
23.6  
27.2  
35.6  
43.5  
80  
94  
110  
124  
156  
186  
36  
36  
36  
36  
36  
36  
50  
50  
50  
50  
50  
50  
600  
700  
78,500  
825  
102,360  
136,480  
157,000  
925  
1175  
1400  
40  
50  
136,480  
157,000  
204,720  
235,500  
341,200  
96.2  
120.3  
144.3  
180.4  
240.6  
48.1  
60.1  
CHTV-624-40  
CHTV-624-50  
CHTV-624-60  
CHTV-624-75  
CHTV-624-100  
CHTVO-624-40  
CHTVO-624-50  
CHTVO-624-60  
CHTVO-624-75  
CHTVO-624100  
CHTVW-624-40  
CHTVW-624-50  
CHTVW-624-60  
CHTVW-624-75  
CHTVW-624-100  
CHTVX-624-40  
CHTVX-624-50  
CHTVX-624-60  
CHTVX-624-75  
CHTVX-624-100  
75.0  
106.0  
137.0  
168.0  
218.0  
95  
111  
125  
149  
187  
48  
48  
48  
48  
48  
60  
60  
60  
60  
60  
1200  
1450  
1600  
1900  
2350  
60  
72.2  
75  
100  
90.2  
120.3  
100  
125  
150  
175  
200  
341,200  
392,500  
511,800  
549,500  
682,400  
240.6  
120.3  
150.4  
180.4  
210.5  
240.6  
CHTV-1230-100 CHTVO-1230-100 CHTVW-1230-100  
CHTV-1230-125 CHTVO-1230-125 CHTVW-1230-125  
CHTV-1230-150 CHTVO-1230-150 CHTVW-1230-150  
CHTV-1230-175 CHTVO-1230-175 CHTVW-1230-175  
CHTV-1230-200 CHTVO-1230-200 CHTVW-1230-200  
CHTVX-1230-100  
CHTVX-1230-125  
CHTVX-1230-150  
CHTVX-1230-175  
CHTVX-1230-200  
218.0  
222.0  
263.0  
300.0  
340.0  
111  
129  
149  
167  
187  
54  
54  
54  
54  
54  
66  
66  
66  
66  
66  
2400  
2700  
3100  
3500  
3950  
225  
250  
275  
300  
767,700  
853,000  
271.0  
301.0  
331.0  
361.0  
CHTV-1836-225 CHTVO-1836-225 CHTVW-1836-225  
CHTV-1836-250 CHTVO-1836-250 CHTVW-1836-250  
CHTV-1836-275 CHTVO-1836-275 CHTVW-1836-275  
CHTV-1836-300 CHTVO-1836-300 CHTVW-1836-300  
CHTVX-1836-225  
CHTVX-1836-250  
CHTVX-1836-275  
CHTVX-1836-300  
379.0  
417.0  
455.0  
490.0  
149  
162  
175  
187  
60  
60  
60  
60  
72  
72  
72  
72  
4600  
5200  
5600  
6000  
938,300  
1,023,600  
*All amperes based on 3ph 60 cycle power.  
ASME Relief Valve  
Pressure Gage  
Level Switch  
Hartford Loop  
Spare or Fill  
Inspection Ports (2)  
Vent  
Sight Glass  
H
Heater Terminal Cover  
L
W
© 2010 Chromalox, Inc.  
 
INSTALLATION  
blocks and the ground lug in the heater terminal enclosure.  
CAUTION: Hazard of Electric Shock. The vaporizer  
must be grounded using the grounding means pro-  
vided in the heater terminal box and in the control  
box, and employ wiring in accordance with the  
National Electrical Code.  
C. With all controls mounted on the same skid with the  
hydraulic or mechanical part of the vaporizer. The unit is  
completely wired. The only wiring necessary is to terminals  
L1, L2 and L3 on the main circuit breaker and the ground-  
ing lug in the control panel.  
1. The vaporizer is normally supplied one of three different ways:  
A. Without controls as they are going to be provided by the  
customer. The customer will have to wire from his supplied  
controls to the level or float switch on the vessel, and to the  
heater terminal blocks and the ground lug in the heater ter-  
minal enclosure.  
2. Note: All electrical connections should be checked and tight-  
ened if necessary. These sometimes loosen in transit.  
CAUTION: Hazard of Electric Shock. Disconnect all  
power before servicing the vaporizer.  
B. With controls supplied, but mounted remotely by the user.  
The customer will have to wire from remote controls to the  
level or float switch on the vessel, and to the heater terminal  
WIRING DIAGRAMS  
Typical Wiring Diagram  
15 to 100 kW (All Voltages)  
Typical Wiring Diagram  
125 to 300 kW 440/480 and 550/575V  
Circuit  
Breaker  
Circuit  
Breaker  
C1  
F1  
F2  
F3  
C1  
C2  
C3  
C4  
L1  
L2  
L3  
L1  
L3  
F1  
F2  
F3  
L2  
F7  
F8  
F9  
F4  
F5  
F6  
F10  
F11  
F12  
C2  
F4  
F5  
F6  
F14  
F13  
H4  
F7 F8  
H4  
H4 H2 H3 H1 H4 H2 H3 H1  
H2  
H4 H2 H3 H1 H4 H2 H3 H1  
240V 480V  
Transformer Primary  
H3  
H1  
240V  
480V  
H1  
H3  
H2  
Transformer Primary  
F15  
On  
F9  
X1  
X2  
Pilot LIght  
R
G
Off  
Feed or Condensate  
Return Pump (Optional)  
Pilot Light  
Low Level and  
High Limit Circuit  
3
4
X1 120-Volt X2  
4
M
Pilot Light  
R
G
A
A
FS2  
FS1  
Off  
OPC  
On  
On  
FS2  
Feed or Condensate  
Return Pump (Optional)  
Pilot Light  
OPC  
7
5
6
M
3
5
7
1CR  
FS-1  
1CR  
CR  
X2  
X1  
High Limit Circuit  
Pilot Light  
Heat #1  
Pilot Light  
6
Off On  
Pilot Light  
Heat #1  
Pilot LIght  
Heat #2  
Pilot LIght  
Heat #3  
Pilot LIght  
Heat #4  
A
A
A
A
1CR  
8
PSI-1  
Off  
Off  
9
C1  
C2  
C3  
C4  
C1  
C2  
1
2
3
4
Stepper  
9
8
Off On  
Off On  
Off On  
A+  
10  
12  
14  
4-20MA  
11  
1CR  
On PSI-2  
10  
Input  
B-  
Heat #2  
11  
12  
13  
15  
C
D
E
135 ohm  
Input  
OPERATION  
CAUTION: To avoid possible damage to the heaters, do not ener-  
float switch located on the vessel, so that the heating element  
will shut off automatically in case of a low liquid level.  
4. Operate the vaporizer until 220°F is reached. Periodically open  
the bleed valves to remove air from the system. At 220°F any  
moisture that has been trapped in the system will flash into  
steam and can be bled off through the bleeder valves.  
gize the heaters until the vaporizer is filled with fluid.  
1. The filling of the Chromalox CHTV type horizontal vaporizer  
is accomplished in one of two ways:  
A. On vaporizers with gravity return type condensate return  
systems, the filling is done simply by pouring the heat  
transfer or other organic media into the vaporizer shell  
using the spare or fill nozzle and, while the filling is taking  
place, bleeding the displaced air from the vent.  
B. On vaporizers that use pump condensate return systems or  
on systems where the condensate is not returned, the filling  
would be done by first filling the condensate return tank or  
supply or reservoir tank and then energizing the condensate  
return or supply pump. While the vaporizer vessel is being  
filled, the vent nozzle should be opening for bleeding out  
the air.  
WARNING: Avoid having the heat transfer fluid or the fluid to be  
vaporized spilled or leaked into the pipeline or vessel insulation as  
it has been found that spontaneous ignition of some of these fluids  
may result at elevated temperatures.  
5. After the vaporizer has been completely charged and free of  
steam pockets, set the controlling pressure switch or thermostat to  
the pressure or temperature point where the fluid will vaporize.  
6. Operate the vaporizer until this set point is reached.  
Periodically open the bleeder valves to remove air from the  
system.  
2. Set the thermostat at 220°F and/or the controlling pressure  
switch at its equivalent.  
3. To energize the heaters, turn the “on-off” selector switch to the  
“on” position. The heaters are interlocked with the level or  
7. After the system is completely free of air, set the controlling  
pressure switch or thermostat to the desired operating point.  
 
MAINTENANCE  
2. The tank should be checked regularly for sediment around the  
CAUTION: Hazard of Severe Shock. Disconnect all  
power to heater before servicing or replacing  
heaters.  
heater as sediment can act as an insulator and shorten heater life.  
3. Remove any accumulated sludge deposits form heater and  
from tank.  
1. Heaters should be checked periodically for coatings and corro-  
4. Check for loose terminal connections and tighten if necessary.  
sion and cleaned if necessary.  
RENEWAL PARTS IDENTIFICATION  
Vaporizer  
Model No.  
Heating Element Part Number  
CHTV, CHTVO, CHTVW  
or CHTVX  
240V  
480V  
316-15  
316-20  
316-25  
316-30  
316-40  
316-50  
063-122121-001  
063-122121-003  
063-122121-005  
063-122121-007  
063-122121-013  
063-122121-017  
063-122121-002  
063-122121-004  
063-122121-006  
063-122121-008  
063-122121-014  
063-122121-018  
624-40  
624-50  
624-60  
624-75  
624-100  
063-122121-003  
063-122121-005  
063-122121-007  
063-122121-011  
063-122121-017  
063-122121-004  
063-122121-006  
063-122121-008  
063-122121-012  
063-122121-018  
1230-100  
1230-125  
1230-150  
1230-175  
1230-200  
063-122121-005  
063-122121-009  
063-122121-011  
063-122121-015  
063-122121-017  
063-122121-006  
063-122121-010  
063-122121-012  
063-122121-016  
063-122121-018  
1836-225  
1836-250  
1836-250  
1836-300  
063-122121-011  
063-122121-012  
063-122121-019  
063-122121-020  
063-122121-018  
063-122121-017  
Limited Warranty:  
Please refer to the Chromalox limited warranty applicable to this product at  
2150 N. RULON WHITE BLVD., OGDEN, UT 84404  
Phone: 1-800-368-2493  
 

Beko Washer D2 8101 ES D2 8101 E User Manual
Belkin Network Router 8820ED00378_F7D4301_V1 User Manual
Best Ventilation Hood ISER222 SERIES User Manual
Bosch Power Tools Saw 1584DVS User Manual
BOXLIGHT Projector XP 8T User Manual
Bradford White Corp Water Heater GX2 25S User Manual
Bravetti Fryer F1100H User Manual
Breville Kitchen Grill BSG220 User Manual
Broan Stove RMIP33 User Manual
Christie Digital Systems Projector 38 VIV301 01 User Manual